delta wb analyzer (Rotem Industries)
Structured Review

Delta Wb Analyzer, supplied by Rotem Industries, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/delta wb analyzer/product/Rotem Industries
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Effects of platelet-sparing leukocyte reduction and agitation methods on in vitro measures of hemostatic function in cold-stored whole blood"
Article Title: Effects of platelet-sparing leukocyte reduction and agitation methods on in vitro measures of hemostatic function in cold-stored whole blood
Journal: The journal of trauma and acute care surgery
doi: 10.1097/TA.0000000000001870
Figure Legend Snippet: Viscoelastic measures in nonleukoreduced and leukoreduced WB units over time. This figure shows viscoelastic measures of non-LR (blue bars) and LR (green bars) whole blood units over 15 days. These include the MCF measured by ROTEM (A), MA measured by TEG (B), TEG MA-ADP (C), and TEG MA-AA (D). Median measurements of MCF, TEG MA, TEG MA-ADP, and TEG MA-AA were compared at each time point between LR and non-LR groups, and absolute median measurements were compared from Day 0 to Day 15 within LR or non-LR groups. Differences are indicated by *p < 0.05, **p < 0.01, ***p < 0.001.
Techniques Used:
Figure Legend Snippet: Viscoelastic measures in leukoreduced WB units by agitation method over time. This figure shows viscoelastic measures of LR WB units by differing agitation method over 15 days. Agitation methods included un-rocked (blue bar; none), up and down shake (green bar), continuous mechanical horizontal agitation via flat rocker (yellow bar), or continuous end-over-end rocking via a 360° rotator (red). The viscoelastic parameters measured include the MCF measured by ROTEM (A), MA measured by TEG, (B), TEG MA-ADP (C), and TEG MA-AA (D). Median measurements of MCF, TEG-MA, TEG MA-ADP, and TEG MA-AA were compared at each time point. No differences were noted. Median measurements of MCF, TEG-MA, TEG MA-ADP, and TEG MA-AA were compared within each agitation group from Day 0 to Day 15. Differences are indicated by *p < 0.05, **p < 0.01, ***p < 0.001.
Techniques Used:
Figure Legend Snippet: Viscoelastic measures in nonleukoreduced WB units by agitation method over time. This figure shows viscoelastic measures of non-LR WB units by differing agitation method over 15 days. Agitation methods included un-rocked (blue bar; none), up and down shake (green bar), continuous mechanical horizontal agitation via flat rocker (yellow bar), or continuous end-over-end rocking via a 360° rotator (red). Viscoelastic parameters measured include MCF measured by ROTEM (A), MA measured by TEG (B), TEG MA-ADP (C), and TEG MA-AA (D). Median measurements of MCF, TEG-MA, TEG MA-ADP, and TEG MA-AA were compared at each time point, and absolute median measurements were compared within each agitation method form Day 0 to Day 15.Differences are indicated by *p < 0.05, **p < 0.01, ***p < 0.001.
Techniques Used: